Seebeck Effect Measurement System
The SB1000 Digital Seebeck Controller from Transient Signal Technologies delivers highly accurate, highly reproducible Seebeck coefficient measurements, using a differential technique with amplification inside the vacuum environment. Paired with the DC600 temperature controller, the system measures bulk materials, thin films, and nanomaterials from 80 K to 700 K.
SB1000 Digital Seebeck Controller by Transient Signal Technologies
Temperature Options
From Room Temperature to 700 K
The SB1000 measures at room temperature on its own. Add a temperature controller with an LN2 cryostat, a hot stage, or both to measure across a wider range.
A Typical Variable Temperature System Includes
-
DC600 Programmable Temperature Controller and SB1000 Seebeck Effect Measurement Controller
-
Liquid nitrogen cryostats with integrated amplification circuitry into the vacuum environment
-
Kapton (80 K to 400 K) or ceramic (200 K to 700 K) sample mounting stages
-
Vacuum pump and vacuum accessories
-
Four soldering pins for electrical conductivity measurements by two probe or four probe technique
-
Dell Optiplex 7000 Tower desktop computer and 22” LCD monitor
-
All electronics mounted in 19” electronic rack
Applications
Metals to Semi-Insulators
Easy measurement of samples ranging from metals to semi-insulators, in single step operation against an internal reference material.
-
Bulk materials
-
Thin films
-
Nanomaterials
-
Thermoelectric materials research
Features
Built for High Signal-to-Noise Seebeck Measurement
Differential Measurement
Differential measurement technique of Seebeck coefficient with high signal-to-noise ratio.
In-Vacuum Amplification
Special amplification circuitry integrated into the vacuum environment allows high SNR.
Fast Data Acquisition
High data acquisition speed allows statistical measurements and analysis, with real-time thermal voltage transient measurements.
Variable Temperature Gradient
Vary the temperature gradient across the sample by applying selected power, 10 mW to 1 W, to the Seebeck heater.
Built-In Reference
Fully automated control with built-in reference, and single step operation against an internal reference material.
Compact Controller
Half-wide, full-length standard rack mount size, 5 lb (2.3 kg). Integrates into a rack mounted cabinet with a shelf.
Sample Stages
Low and High Temperature Mounting Stages
Each system is supplied with sample mounting stages for low temperature and high temperature operation. Each stage has an installed Seebeck heater for accurate temperature gradient control across the sample under test.
Software
Automated Setup, Exportable Reports
A user-friendly, automated measurement setup with statistical data analysis. Reports are generated directly through the software suite.
-
Export to PNG, JPG, TXT, and CSV
-
Windows® 10 and Windows® 11
-
USB or serial port connection
-
32-bit or 64-bit hardware
Software screenshot needed
Measurement setup
Software screenshot needed
Thermal voltage transient
Software screenshot needed
Statistical analysis and report
Related systems
Pair Seebeck Data with Hall and Resistivity
Talk to Us About Your Thermoelectric Samples