HL9900 Hall Effect Measurement
HL9900 is a turnkey, high performance hall effect system for the measurement of resistivity, carrier concentration, and mobility in semiconductors. Modular in concept, allowing easy upgrade paths, the system is suitable for a wide variety of materials, including silicon and compound semiconductors.
HL9900 with original Nanometrics core technology inside
Models
One Hall System, Two Upgrade Modules
The HL9900 standard system covers low and high resistivity samples. The HL9980 buffer amplifier extends measurement to very high resistivity, and the HL9950 variable temperature unit adds measurement from 90 K to 500 K.
Standard system
HL9900
Turnkey Hall system for sheet resistivities from 0.1 mΩ/square to in excess of 1 MΩ/square. Supplied with a two-temperature measurement stage complete with removable dewar and four micromanipulator probes.
Side by Side
HL9980 and HL9950 are modules added to the HL9900 system. The HL9950 is fully compatible with the HL9980; with the buffer amplifier attached, the measurement circuit switches over automatically when sample current falls below 0.1 µA. On mobile, the table shows the model selected above.
Applications
What Hall Effect Measurement Determines
HL9900 has both low and high resistivity measurement capabilities.
-
Resistivity/Conductivity
-
Mobility
-
Bulk/Sheet carrier concentration
-
Doping type
-
Hall coefficient
-
Magnetoresistance
-
Vertical/Horizontal ratio of resistance
Features
Built for Fast, Accurate Hall Measurement
ASTM F-76 Sample Support
Van der Pauw, Hall Bar and Bridge measurements to ASTM F-76 standard, with correction for Hall scattering factor.
Simple Probe System
Simple probe system for convenient, fast sample throughput, in a compact bench top design. The measurement head is supplied with a two-temperature measurement stage complete with removable dewar and four micromanipulator probes.
Auto-Current Facility
A wide current range including auto-current facility in order to minimize sample heating.
Electric Field Limitation
User defined electric field limitation to avoid impact ionization effects at low temperatures.
AC/DC Measurement Modes
AC/DC measurement modes, using AC currents and phase sensitive detection.
Optional Buffer Amplifier
Optional high impedance buffer amplifier/current source to extend sheet resistivity measurements to 10¹¹ Ω/square.
Magnet
Permanent Magnet with Field Reversal
The HL9900/M50 uses a 0.5 T permanent magnet (nominal), with field reversal by magnet.
Software
No Programming Experience Required
With an intuitive user interface, no programming experience is required to set up or use the HL9900.
-
Van der Pauw, Hall Bar and Bridge measurements to ASTM F-76 standard
-
Correction for Hall scattering factor
-
Auto-current facility in order to minimize sample heating
-
User defined electric field limitation to avoid impact ionization effects at low temperatures
HL99WIN results and temperature scan table
I-V curve contact check
HL9950 temperature control settings
Related systems
Pair Hall Data with Doping, Resistivity, and Seebeck
Evaluate the HL9900 on Your Samples
Send samples to our Chicago lab. An applications engineer will measure them and recommend the right configuration.