ECVPro+ Advanced Electrochemical Capacitance Voltage

The Toho ECVPro+ is a market-leading, all-in-one system for carrier concentration profiling in semiconductor materials. Combining superior measurement capabilities, intuitive workflow, robust design, flexible software, and global support, the ECVPro+ sets the standard for advanced semiconductor characterization.

ECVPro+ electrochemical CV profiler

ECVPro+ floor standing profiler

10¹² to 10²¹ cm⁻³ Carrier concentration range*
1 nm Depth resolution*
0.05 to 50 µm Depth range*
0.3 to 5.5 kHz Dual-frequency carrier range

*Dependent on material quality.

Overview

A Total Redesign of ECV Profiling

The patent-pending ECV Pro + is the result of a total redesign that completely redefines ECV profiling. We have taken 25 years of ECV profiling experience and coupled it with 25 years of advances in instrument control technology to produce the most precise, most reproducible, most highly-automated electrochemical CV profiler ever.

Leveraging advanced electrochemical etching and capacitance measurement techniques, the ECVPro+ delivers accurate, layer-by-layer insight into dopant distribution, carrier type (n or p), and depth profiling across complex epitaxial structures.

Applications

Comprehensive Material Range

With support for a wide range of semiconductor materials, including wide bandgap compounds like GaN, InGaN, and AlGaN, the ECVPro+ is essential for developing next-generation devices in power electronics, optoelectronics, quantum computing, and more.

Materials and Structures

  • III-V, II-VI, and IV semiconductors (e.g., GaAs, InP, GaN, SiC, ZnO, CdTe)

  • Complex epitaxial structures and p-n junctions

  • Nanomaterials, quantum dots, and IR sensors

Hg Probe Alternative

The ECV Pro’s accuracy and reproducibility provide a viable, safe and environmentally friendly alternative to the Mercury probe. ECV Pro uses no Calomel reference electrode and is entirely Mercury free. The horizontal stage makes monitoring spatial distribution across a wafer simple and convenient. Using the depletion profile mode and the ultra-repeatable contacting area, ECV Pro can accurately measure the surface doping variations across a wafer.

Alternative to Hall

ECV Pro offers many advantages over Hall measurements. These include measurement of electrically activated dopants and individual structural layer information. Additionally, the ECV Pro can be applied to a wide range of materials and structures and is not limited to profiling only on Si or suitable PN structures.

Measurement Capabilities

Most Advanced Measurement Capabilities

  • Built-in blast contact feature allowing for uniform oxide removal

  • Dual-frequency and AC measurement modes for enhanced sensitivity

  • Real-time etch visualization and interface analysis

ECVPro+ blast contact probes
Etch current during oxide growth and removal

ECVision™ Imaging

ECV Pro introduces the first ever in-situ camera for unprecedented levels of control, ECVision™, allowing real-time imaging of the semiconductor/electrolyte interface. Now you can see exactly what occurs at the sample surface during a measurement. For III-Nitrides, the ECV Pro GaN option extends the performance of the system for optimal profiling of GaN, InGaN and AlGaN.

Camera Monochrome JAI GO-5101M-PMCL
Resolution 5.1 MP, Visible + NIR
Performance High sensitivity, sharpness, and low-light performance

ECVision is enabled by optimum surface reflection.

Workflow

3-Step Operation, Simplest Workflow

Eliminate Operator Variability. Operator training time is reduced. Sample preparation is simplified and the intuitive software leads the operator through the measurement process step by step reducing the possibility of errors.

01

Load Sample

Load sample on vacuum stage.

02

Make Contact

Make contact with probes.

03

Lock & Measure

Automated recipe handles the rest.

Loading a sample on the ECVPro+ vacuum stage
Making contact with probes
Locking the cell before measurement

Design

Superior Design

System Highlights

  • Built-in blast contact (40V) ensures consistent Ohmic contact

  • Platinum reference electrode eliminates manual calibration

  • No need for mercury-based electrodes or manual adjustments

Cell Assembly & Sealing Rings

  • Tool-free, 2-step sealing ring mounting

  • Built-in counterweight for uniform pressure

  • Optimized electrolyte circulation for consistent etching

Fluid Handling System

  • Vacuum-based manifold for electrolyte and DI water

  • Chemically resistant tubing with leak-proof design

  • Automatic fill, drain, and wash sequences

Lower Cost of Ownership

  • The novel design extends the sealing ring lifetime and eliminates the cost of expensive Calomel electrodes

  • Signal electrodes and contact sets need less frequent replacement

  • The floor standing design reduces footprint by approximately a factor of two compared with other profilers

  • As the electrolyte and waste are contained on the unit, there is no need for an adjacent wet-bench

JAI camera used for ECVision imaging
Mounting the sealing ring
Cell assembly

Software

Recipe Automation, Dynamic and Flexible Software

Recipe-driven operation means no operator involvement when profiling complex structures.

  • Create and run complex etch profiles without supervision

  • Pause to measure IV, CV, depletion profiles, or switch electrolytes

  • Automated lamp intensity adjustment for consistent etch rates

ECVPro+ software carrier concentration profile
ECVision image capture in the ECVPro+ software
ECVPro+ recipe files

Global Support

Unmatched Global Support

300+ Systems installed worldwide
5+ Support centers in Chicago, San Jose, Paris, Tokyo, Shanghai, and more
3 Applications labs in California, Japan, and China

Evaluate the ECVPro+ on Your Samples

Send samples to our Chicago lab. An applications engineer will profile them and recommend the right configuration.

Scroll to Top